CVM AND CONVERTIBLE TOP PDF

SOFTWARE PRICES and ORDER FORM – Australia – Sidrasolutions: Akcelik & Associates Pty Ltd P O Box G, Greythorn Victoria Australia Telephone . The convertible top module (CVM IV) controls and monitors the hydraulic and electrical drive and locking components of the folding top. The most common failure on the E46 convertible top is that the hydraulic cylinders leak. .. The CVM (convertible top module) is on the drivers side, thus why the.

Author: Meztizahn Gazil
Country: Saint Kitts and Nevis
Language: English (Spanish)
Genre: Video
Published (Last): 6 September 2016
Pages: 442
PDF File Size: 2.74 Mb
ePub File Size: 19.73 Mb
ISBN: 201-9-24893-630-5
Downloads: 29363
Price: Free* [*Free Regsitration Required]
Uploader: Meziktilar

The hard top lock post and storage cover locks must be removed from the top frame assembly. Add to Watch list Watching. Two LEDs are positioned in the center of the switch. Seller assumes all responsibility for this listing. How many hydraulic solenoids are used in the operation of the E46iC top?

An angle hall sensor is used to detect the posi- tioning of the main top linkage. The signal from the variable storage compartment floor micro switch will prevent the stor- age cover from opening when the floor is in the open position.

The E46 Convertible-top is a fully automatic electro-hydraulic system that completely opens and closes the soft-top using hydraulic cylinders and electric motors. The frame of the manual top is similar to the fully automatic system, with two piston dampers mounted on the assembly to aid in its operation. The tension bow lower solenoid is switched to drain. Learn more about your rights as a buyer. If the temperature exceeds C, the system is immediately switched 0 off and the emergency closing procedure will be required for closing the top.

BMW 6 Series CVM Module 6949964 Convertible Top Controller

Learn More – opens in a new window or tab International cv, and import charges paid to Pitney Bowes Inc. The item may have some signs of cosmetic wear, but is fully operational and functions as intended. No additional import charges on delivery.

Last Drivers  SONY BRAVIA EX52 MANUAL EBOOK DOWNLOAD

What type of input is provided by the angle hall sensors for top operation? When the cover is low- ered, the solenoid switches to drain and the lowering pressure closes the cover. Get the item you ordered or your convsrtible back.

Add to basket.

Mini Workshop Manuals

During the soft top operation, when the tensioning bow is raised converyible when the top is in the storage compartment, the CVM signals the GM over the K-Bus to unlock the storage com- partment cover.

Learn More – opens in a new window or tab Any international postage is paid in part to Pitney Bowes Inc.

Compatibility information isn’t available for this item. The hydraulic operation of the solenoids and cylinders is as follows: The latch brackets are mounted through elongated holes for alignment of the brackets to the cover latches.

There are three connectors on each side of the top assembly in front of the top stor- age compartment. I, pressure deactivation is the drain solenoid for relieving pressure in the hydraulic cylinders when the key is switched off. Help Center Find new research papers in: Make offer – Loading This allows the pressure in the cylinders to be relieved and drained back to the reservoir.

Bitte vor dem Kauf Teilenummer und Foto vergleichen!! The greater pressure on the raise side of the piston will overcome the lowering pressure to raise the frame. The drain solenoid also holds system pressure when the top switch is released during operation.

This listing is for the part or sub-assembly number shown below only. The CVM uses the input signal of the hall sensor to lock out soft top operation while the hard top is installed.

It receives power and ground from the CVM. I, extend tensioning bow controls the tension bow hydraulic cylinders for lowering. It is mount- ed on a rubber bushing and covered by sound insulation for noise reduction during pump operation. Economy Delivery Economy Int’l Versand. What are the major convvertible to the E46iC fully automatic top operation compared to the E36iC? Select a valid country. This item will be sent through the Global Shipping Programme and includes international tracking.

Last Drivers  GARG SANHITA PDF DOWNLOAD

The storage cover is then lowered onto the locks and the signals from the storage cover hall sensors will signal the GM to relock the cover.

Table of Contents CVM AND CONVERTIBLE TOP | Stefano Pignataro –

The motor assembly is accessed by removing the center arm rest and lifting the seat uphol- stery below the ski bag. The ignition switch must be cycled to clear the fault before the top will again function.

Convertjble item fits with these vehicles: Removal of the soft top assembly coonvertible removing the rear seat and interior trim panels to gain access to the fastening points and wiring con- nections. Hop up for newsletter. Log In Sign Up. Depending on the position, the top may collapse into the storage compartment if the ignition is switched off with the top in the partially raised position. Enter the email address you signed up with and we’ll email you a reset link.

If you have questions about this VAT, please contact the seller. Operation of the hydraulic cylinders is controlled via final stages and solenoids mounted on the hydraulic unit and top frame.

This allows the top to be manually moved for servicing procedures. When the floor is in the raised position, the soft top operation is locked out. An item that has been previously used.